Infant Care Equipment Transport Incubator for Baby

Infant Care Equipment Transport Incubator for Baby
Infant Care Equipment Transport Incubator for BabyInfant Care Equipment Transport Incubator for Baby
group name
Infant Incubator
Min Order
1 piece
model
CNME010701
payment method
L/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal
update time
Thu, 29 Jul 2021 09:57:18 GMT

Paramtents

  • Type Infant Incubator

  • Function Warmer

  • Theory Electrotherapeutics

  • Certification CE

  • Dimension (Main Body) 1090mm*655mm*760mm

  • Temperature Control Mode Air Mode and Baby Mode

Packging & Delivery

  • Min Order1 piece

Briefing

Infant Care Equipment,Two temperature control modes: Air mode and Baby mode controlled by micro-computer .

Detailed

Infant Care Equipment Transport Incubator for Baby

Basic Info.
Model NO.
CNME010701
Standard Configuration
Main Body, Oxygen Cylinders, I.V. Pole etc
Optional Configuration
>37ºC
Air Temperature Control Range
25°c - 37°c
Baby Temperature Control Range
34°c- 37°c
Skin Temperature Sensor Accuracy
±0.2°c
Battery Continuous Working Time
90min
Origin
China
Infant Care Equipment Transport Incubator For Baby
Brief Introduction:
Two temperature control modes: Air mode and Baby mode controlled by micro-computer;
Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;
Set temperature, Air temperature, Baby temperature and Internal battery capacity can be displayed separately;
Multiple failure alarm indications;
">37 °C" temperature set function as optional configuration;
Double wall acrylic glass hood with side door so that the bassinet can be pulled out from it;
Passive humidification;
The height of whole unit can be adjusted;
Oxygen supply system;
Observation lamp.
Standard Configuration:
Main body (Including the Hood, Controller, Bassinet, Internal battery, and Observation Lamp), Oxygen cylinders, Oxygen supply system, Skin temperature sensor, I.V. Pole, Mattress, Adjustable stand).
Specification:
Product name
Infant Care Equipment Transport Incubator for Baby 
Control Mode
Air mode and Baby mode controlled by micro-computer
Air temperature control range
25°C-37°C(Override mode 37°C-38°C)
Baby temperature control range
34°C-37°C(Override mode 37-37.5°C)
Skin temperature sensor accuracy
±0.2°C
Temperature uniformity
≤1.5°C(mattress is on the horizontal position)
Noise inside hood
≤52 dB(A)
Failure alarm
over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, and so on.
Battery continuous working time
90min (Set temperature is 36°C- Ambient temperature is 15°C)
Infant Incubator Product Packaging:
L*W*H: 2100*700*445mm
N.W: 69KG
More Options for your selection